Chloride® CP70i DC/AC Inverter

CP as Customized Product. The most advanced product in terms of possibilities.

Enquire

UPS TypeDC/AC IEC/NEC

Ratings5 to 320 kVA

TechnologyIGBT

Chloride® CP70i DC/AC Inverter

CP as Customized Product. The most advanced product in terms of possibilities.

Enquire

UPS TypeDC/AC IEC/NEC

Ratings5 to 320 kVA

TechnologyIGBT

You are currently viewing: North America Products

Market & Industry Type

  • Power generation plants

  • Transmission and Distribution substations

  • Oil & Gas industries, offshore and onshore

Features & Benefits

Read less Read more

Availability

Maintainability

The easiest on the market with total components front access.

Reliability

Innovative internal temperature reduction, through dual redundant cooling channels.

Multiplied redundancy with Chloride® Patented Smart Parallel Switching function that dynamically controls paralleled systems.

Key advantages

User friendly

Large color touch screen with 2000-event exportable log.

One of the best on the Industrial UPS Market.

USB access

Export of all the recorded events using USB flash drive.

Memorization of complete electronic settings for future maintenance needs.

Batteries compatibility

Innovative full integration with SMC/Salt Batteries (Sodium Metal Chloride Batteries).

Full compatibility with Lead-acid, nickel-cadmium batteries, sealed or vented and Lithium-Ion.

Life time

Designed for 20+ years of continuous operation with appropriate maintenance plan.

Input

DC voltage

125V ; 220V ; 400V 

Input voltage range

88-156 V 176-305 V296-507 V

Output

AC Voltage Single phase

1 x 230 V (220, 240) ; 1 x 110 V (115, 120)

AC Voltage Three phase

3 x 400 V (380, 415) ; 3 x 220 V (200, 208, 230)

Frequency

50 Hz (60 Hz)

Frequency stability with internal oscillator

+/- 0.05%

Frequency stability with reserve synchronism

+/- 3 % (from 1 to 5% adjustable)

Voltage stability (for 0 to 100 % load variation): Static

+/-1 % (+/-2 % for parallel systems)

Dynamic

VFI SS 111 as per IEC/EN 62040-3, class 1

Inverter overload capability: 1 minute

150 % of nominal power

Inverter overload capability: 10 minutes

125 % of nominal power

Short-circuit clearance (in % of nominal current)

1-ph output : 250 % / 100ms - 175% / 5s

3-ph output Ph-N

315 % / 100 ms - 220 % / 5 s

3-ph output Ph-Ph

190 % / 100 ms - 135 % / 5 s

Harmonic voltage distorsion

With 100 % linear load < 3 %

Harmonic voltage distorsion

With 100 % non-linear load : SS as per IEC/EN 62040-3

Allowable power factor

0,5 lagging to 0,5 leading

General Data

Operating temperature

32 to 104 °F (other on request)

Storage temperature

-4 to 158 °F

Relative humidity

< 95% non condensing

Operating altitude

3200 feet max without derating

Cooling

Forced ventilation

Efficiency

Up to 91% according to rating

External protection

NEMA 1 / IP 20 according to IEC 60529

Internal protection

Protection against unintentional direct contacts, as per IEC 60950-1

Noise (at 1m in front of the unit)

60-75 dB according to rating

Cabinet colour

Grey RAL 7032

Dimensions

Varying according to ratings and options

Ratings

Output power (kVA)

5 to 500

DC Input voltage (Vdc)

125 - 220 - 400

Options

Inverter

Automatic precharge of capacitors

Onther output voltage (1 x 110 to 3 x 690 VAC)

Inverter oversizing

By pass line

Bypass isolator(s)

Bypass transformer (H class)

Bypass stabilizer (servo-controlled)

Backfeed protection

System

Inverter with or with bypass line

Parallel configurations

Input / output isolators

AC Distribution

Earth fault detection or monitoring

Internal lighting

Anti-condensation heater

Cabinet temperature monitor

Mechanical

External ingress protection up to IP42

Top cable entry

Specified color of panels

Special feet height (200mm or 300mm)

Special keylock

Non-magnetic gland plate (brass or aluminum)

Lifting eyes

2 mm side panels thickness

Specified cabinet identification (tag, nameplate)

Anti-seismic design

Communication

Front panel analogue meters(72x72, class 1.5 or class 1)

Transducers 4-20mA

Additional volt-free contacts

Modbus RTU (RS232 or RS485)

Modbus / TCP

Profibus

IEC61850 protocol

Mimic panel on front:• Passive mimic of the system• Active mimic with integrated LEDs

Lamp indicator on front panel (22 mm diameter)

Standards

UL 1778, fifth edition 2014

Standard for safety - Uninterruptible power systems

NEMA PE1 2012

Uninterruptible power systems (UPS) – Specification and performance verification